Rotary Switch Sections - Page 82 of 123

3055 part numbers
4L7089-5
View Part NSN 5930-00-823-4738 Cross Reference: 906-4
  • Overall Diameter: 1.030 inches
  • Switch Contact Basic Design: Nonpile-up nonsymmetrical
  • Mounting Method: Strut single mounting facility
  • Terminal Type: Tab, solder lug
  • Contact Switching Action: Makes before breaks single section front
4L7089-6
View Part NSN 5930-00-823-4754 Cross Reference: 417089-6
500-0085-00
View Part NSN 5930-00-327-8736 Cross Reference: 5645-30, ML7469267-1
  • Mounting Method: Strut single mounting facility
  • Mounting Facility Pattern: Two position in-line single mounting facility
500-0206-00
View Part NSN 5930-00-636-2582 Cross Reference: 564540
  • Overall Height: 2.812 inches
  • Switch Contact Basic Design: Nonpile-up symmetrical
  • Pole Quantity: 2 single section rear
  • Throw Quantity: 9 single section front
  • Mounting Method: Strut single mounting facility
500-0427-002
View Part NSN 5930-00-369-8384 Cross Reference: 500-0427-00B, SA1435
  • Overall Height: 1.875 inches
  • Overall Width: 1.718 inches
  • Switch Contact Basic Design: Nonpile-up symmetrical
  • Pole Quantity: 1 single section front
  • Throw Quantity: 6 single section front
500-0427-00B
View Part NSN 5930-00-369-8384 Cross Reference: 500-0427-002, SA1435
  • Overall Height: 1.875 inches
  • Overall Width: 1.718 inches
  • Switch Contact Basic Design: Nonpile-up symmetrical
  • Pole Quantity: 1 single section front
  • Throw Quantity: 6 single section front
500-0850-000
View Part NSN 5930-00-369-8473
500-6617-00C
View Part NSN 5930-00-636-2580
  • Overall Height: 2.812 inches
  • Overall Width: 2.000 inches
  • Body Thickness: 0.250 inches
  • Switch Contact Basic Design: Nonpile-up symmetrical
  • Pole Quantity: 2 single section rear
50093HS
View Part NSN 5930-00-041-3640 Cross Reference: 269-1388-00
  • Switch Contact Basic Design: Nonpile-up nonsymmetrical
  • Mounting Method: Strut single mounting facility
501147
View Part NSN 5930-00-310-8729 Cross Reference: 355-161-011, CS1
50143
View Part NSN 5930-01-048-7549 Cross Reference: 269-2358-00, 4-2556-520
  • Overall Height: 1.578 inches
  • Overall Width: 1.422 inches
  • Switch Contact Basic Design: Nonpile-up nonsymmetrical
  • Mounting Method: Strut single mounting facility
  • Contact Voltage Rating In Volts: 115.0 ac at sea level
50143-4MLR
View Part NSN 5930-00-945-0102 Cross Reference: 269-2358-000
50148
View Part NSN 5930-00-945-0085 Cross Reference: 269-2356-000, 50148-414LW-W
  • Hazardous Locations/environmental Protection: Dustproof
  • Overall Height: 1.375 inches
  • Overall Width: 1.062 inches
  • Body Thickness: 0.375 inches
  • Unthreaded Mounting Hole Diameter: 0.094 inches single mounting facility
50148-414LW-W
View Part NSN 5930-00-945-0085 Cross Reference: 269-2356-000, 50148
  • Hazardous Locations/environmental Protection: Dustproof
  • Overall Height: 1.375 inches
  • Overall Width: 1.062 inches
  • Body Thickness: 0.375 inches
  • Unthreaded Mounting Hole Diameter: 0.094 inches single mounting facility
502-0120-002
View Part NSN 5930-00-412-2231
  • Overall Diameter: 2.032 inches
  • Body Thickness: 0.078 inches
  • Longest Horizontal Distance Between Mounting Centers: 1.562 inches 2nd mounting facility
  • Switch Contact Basic Design: Nonpile-up symmetrical
  • Pole Quantity: 1 single section rear
502-0806-003
View Part NSN 5930-00-340-2932
  • Overall Height: 2.813 inches
  • Overall Width: 2.000 inches
  • Switch Contact Basic Design: Nonpile-up nonsymmetrical
  • Mounting Method: Strut single mounting facility
  • Contact Voltage Rating In Volts: 28.0 dc at sea level
502-1748-002
View Part NSN 5930-00-412-2199
  • Switch Contact Basic Design: Nonpile-up symmetrical
  • Pole Quantity: 1 single section rear
  • Throw Quantity: 5 single section rear
  • Mounting Method: Strut single mounting facility
  • Contact Voltage Rating In Volts: 115.0 ac at sea level
50230-4MLR
View Part NSN 5930-00-945-0084 Cross Reference: 269-2357-000
5024-0507
View Part NSN 5930-01-094-1354
  • Overall Diameter: 1.250 inches
  • Body Thickness: 0.061 inches
  • Unthreaded Mounting Hole Diameter: 0.125 inches single mounting facility
  • Distance Between Mounting Facility Centers: 1.000 inches single mounting facility
  • End Application: Rt149 (p)/urc116(v)
5024050703
View Part NSN 5930-01-108-9480 Cross Reference: 4-1723-212
  • Switch Contact Basic Design: Nonpile-up nonsymmetrical
  • Terminal Type: Tab, solder lug
  • Contact Switching Action: Makes before breaks single section front
  • Style Designator: Switch section, rotary
5024-0518
View Part NSN 5930-01-094-6599 Cross Reference: 5024051807
  • Overall Diameter: 1.250 inches
  • Body Thickness: 0.061 inches
  • Unthreaded Mounting Hole Diameter: 0.124 inches single mounting facility
  • Distance Between Mounting Facility Centers: 1.045 inches single mounting facility
  • End Application: Rt1494p/urc116v
5024051807
View Part NSN 5930-01-094-6599 Cross Reference: 5024-0518
  • Overall Diameter: 1.250 inches
  • Body Thickness: 0.061 inches
  • Unthreaded Mounting Hole Diameter: 0.124 inches single mounting facility
  • Distance Between Mounting Facility Centers: 1.045 inches single mounting facility
  • End Application: Rt1494p/urc116v
5024-0528-00
View Part NSN 5930-01-094-1357 Cross Reference: 5024052803
  • Overall Diameter: 1.312 inches
  • Body Thickness: 0.061 inches
  • Unthreaded Mounting Hole Diameter: 0.125 inches single mounting facility
  • Distance Between Mounting Facility Centers: 1.062 inches single mounting facility
  • End Application: Rt1494p/urc116v
5024052803
View Part NSN 5930-01-094-1357 Cross Reference: 5024-0528-00
  • Overall Diameter: 1.312 inches
  • Body Thickness: 0.061 inches
  • Unthreaded Mounting Hole Diameter: 0.125 inches single mounting facility
  • Distance Between Mounting Facility Centers: 1.062 inches single mounting facility
  • End Application: Rt1494p/urc116v
5024-0531
View Part NSN 5930-01-094-1359
  • Overall Diameter: 1.250 inches
  • Body Thickness: 0.061 inches
  • Unthreaded Mounting Hole Diameter: 0.125 inches single mounting facility
  • Distance Between Mounting Facility Centers: 1.000 inches single mounting facility
  • End Application: Rt1494p/urg116v