2a single mounting facility thread class, unef single mounting facility thread series designator.
0.375" single mounting facility thread length 1.297" overall width circular wafer, bushing mount.
Includes quality control certificate of conformance.
-
Thread Length:
0.375 inches single mounting facility
-
Overall Height:
1.375 inches
-
Overall Width:
1.297 inches
-
Flat Height:
0.218 inches single actuator
-
Shaft Diameter:
0.250 inches single actuator
-
Nonturn Device Radius:
0.531 inches at 3: 00 o'clock
-
Individual Section Quantity:
4
-
Nonturn Device Type:
Tab at 3: 00 o'clock
-
Operating Tempurature Range:
-65.0/+125.0 degrees celsius
-
Switch Contact Basic Design:
Pile-up
-
Throw Quantity:
5 1st section rear
-
Throw Quantity:
7 2nd section rear
-
Throw Quantity:
7 3rd section rear
-
Throw Quantity:
7 4th section rear
-
Mounting Method:
Threaded bushing single mounting facility
-
Thread Size:
0.375 inches single mounting facility
-
Contact Voltage Rating In Volts:
30.0 lowest dc voltage rating at sea level
-
Contact Voltage Rating In Volts:
300.0 ac at sea level
-
Contact Voltage Rating In Volts:
300.0 highest dc voltage rating at sea level
-
Switch Actuator Indexing Position Quantity:
7 single actuator
-
Shaft Type:
Round, flatted single actuator
-
Terminal Type:
Tab, solder lug and wire lead
-
Contact Switching Action:
Breaks before makes each section rear
-
Switch Actuator Positioning Increment:
30.0 degrees single actuator
-
Switch Actuator Stop Device Type:
Fixed stop single actuator
-
Contact Load Current Rating:
50.0 milliamperes inductive load lowest dc voltage rating at sea level
-
Contact Load Current Rating:
50.0 milliamperes resistive load highest dc voltage rating at sea level
-
Contact Load Current Rating:
750.0 milliamperes resistive load ac at sea level
-
Precious Material And Location:
Contact surfaces silver
-
Precious Material:
Silver
-
Style Designator:
Circular wafer, bushing mount
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-00-147-8886
-
Special Features:
Terminals three, four and five on section four are electrically wired together