Features
3.344 inches nominal overall length.
1.875" overall width.
Includes quality control certificate of conformance.
Specifications
-
Overall Height:
0.734 inches
-
Overall Width:
1.875 inches
-
Capillary Tube Length:
76.000 inches
-
Bulb Length:
1.500 inches
-
Bulb Diameter:
0.375 inches
-
Tempurature Sensing Element Type:
Capillary tube-bulb
-
Mounting Method:
Base
-
Contact Action Stimulus:
Increase
-
Nonpile-up Contact Arrangement:
1 pole, single throw, normally open, momentary action
-
Terminal Type:
Screw
-
Contact Load Current Rating:
13.0 amperes resistive load second voltage
-
Contact Load Current Rating:
6.5 amperes resistive load first voltage
-
Contact Adjustability:
Actuation point adjustable, preset
-
Contact Adjustment Range:
-15.00/+40.00 actuation point degrees fahrenheit
-
Contact Adjustment Type:
External actuation point knob
-
Contact Voltage Rating In Volts:
115.0 ac at sea level second voltage
-
Contact Voltage Rating In Volts:
230.0 ac at sea level first voltage
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-00-503-4547
-
Special Features:
Two mtg holes tapped no. 10/0.190 in./-32 thd spaced 1.000 in. C to c