Features
4.875 inches nominal overall length.
2.875" overall width rectangular.
Includes quality control certificate of conformance.
Specifications
-
Hazardous Locations/environmental Protection:
Watertight
-
Overall Height:
3.843 inches
-
Overall Width:
2.875 inches
-
Body Length:
4.625 inches
-
Capillary Tube Length:
20.000 inches
-
Bulb Length:
3.625 inches
-
Bulb Diameter:
0.688 inches
-
Tempurature Sensing Element Type:
Capillary tube-bulb
-
Mounting Method:
Surface
-
Contact Action Stimulus:
Increase
-
Nonpile-up Contact Arrangement:
1 pole, single throw, normally open, momentary action
-
Terminal Type:
Connector, receptacle
-
Contact Load Current Rating:
16.0 amperes resistive load second voltage
-
Contact Load Current Rating:
2.0 amperes resistive load third voltage
-
Contact Load Current Rating:
3.2 amperes inductive load first voltage
-
Contact Load Current Rating:
9.6 amperes resistive load fourth voltage
-
Contact Adjustability:
Deactuation point adjustable and actuation point adjustable
-
Contact Adjustment Range:
+185.00/+250.00 actuation point degrees fahrenheit and +185.00/+250.00 deactuation point degrees fahrenheit
-
Contact Adjustment Type:
External deactuation point screw and external actuation point screw
-
Contact Voltage Rating In Volts:
115.0 ac at sea level second voltage
-
Contact Voltage Rating In Volts:
115.0 dc at sea level fourth voltage
-
Contact Voltage Rating In Volts:
550.0 ac at sea level first voltage
-
Contact Voltage Rating In Volts:
550.0 dc at sea level third voltage
-
Media For Which Designed:
Gas or liquid
-
Style Designator:
Rectangular
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-01-051-3303