Features
1.875 inches nominal overall length.
2.594" overall width manual reset button rectangular.
Includes quality control certificate of conformance.
Specifications
-
Hazardous Locations/environmental Protection:
Corrosion resistant
-
Overall Height:
4.188 inches
-
Overall Width:
2.594 inches
-
Body Height:
3.500 inches
-
Capillary Tube Length:
68.0 inches
-
Bulb Length:
3.750 inches
-
Bulb Diameter:
0.375 inches
-
Tempurature Sensing Element Type:
Capillary tube-bulb
-
Operating Tempurature Rating:
Between -150.0 degrees fahrenheit and 570.0 degrees fahrenheit
-
Mounting Method:
Immersion well
-
Features Provided:
Manual reset button
-
Contact Action Stimulus:
Increase
-
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
-
Terminal Type:
Screw
-
Contact Load Current Rating:
5.0 amperes resistive load first voltage3.0 amperes resistive load second voltage
-
Contact Adjustability:
Actuation point adjustable
-
Contact Adjustment Range:
+60.00/+190.00 actuation point degrees fahrenheit
-
Contact Adjustment Type:
External actuation point screw
-
Contact Voltage Rating In Volts:
240.0 ac at sea level first voltage600.0 ac at sea level second voltage
-
Media For Which Designed:
Liquid
-
Style Designator:
Rectangular
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-01-339-4145