Features
8.594 inches nominal overall length.
5.063" overall width calibrated scale rectangular.
Includes quality control certificate of conformance.
Specifications
-
Overall Height:
8.719 inches
-
Overall Width:
5.063 inches
-
Body Height:
7.969 inches
-
Capillary Tube Length:
120.0 inches
-
Bulb Length:
3.750 inches
-
Bulb Diameter:
0.375 inches
-
Longest Horizontal Distance Between Mounting Centers:
8.594 inches
-
Shortest Horizontal Distance Between Mounting Centers:
2.781 inches
-
Longest Vertical Distance Between Mounting Centers:
4.531 inches
-
Tempurature Sensing Element Type:
Capillary tube-bulb
-
Mounting Method:
Bracket
-
Features Provided:
Calibrated scale
-
Contact Action Stimulus:
Increase
-
Mounting Facility Pattern:
Isosceles triangle
-
Nonpile-up Contact Arrangement:
2 pole, double throw, one position momentary
-
Terminal Type:
Screw
-
Contact Load Current Rating:
50.0 amperes resistive load single voltage
-
Contact Adjustability:
Deactuation point adjustable and actuation point adjustable
-
Contact Adjustment Range:
+100.00/+1000.00 actuation point degrees fahrenheit and +95.00/+995.00 deactuation point degrees fahrenheit
-
Contact Adjustment Type:
External deactuation point knob with scale and external actuation point knob with scale
-
Contact Voltage Rating In Volts:
250.0 ac at sea level single voltage
-
Media For Which Designed:
Gas or liquid
-
Style Designator:
Rectangular
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-01-033-7910