Features
Includes quality control certificate of conformance.
Specifications
-
Distance Between Mounting Facility Centers:
2.188 inches
-
Capillary Tube Length:
60.0 inches
-
Tempurature Sensing Element Type:
Capillary tube
-
Mounting Method:
Bracket and unthreaded hole
-
Contact Action Stimulus:
Increase
-
Mounting Facility Pattern:
Two position in-line
-
Contact Load Current Rating:
20.0 amperes resistive load single voltage
-
Contact Adjustability:
Actuation point not adjustable and deactuation point not adjustable
-
Contact Stimulus Rating:
32.00 actuation point degrees fahrenheit and 43.00 deactuation point degrees fahrenheit
-
Contact Voltage Rating In Volts:
240.0 ac at sea level single voltage
-
Media For Which Designed:
Gas or liquid
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-01-202-9300