Features
Includes quality control certificate of conformance.
Specifications
-
Capillary Tube Length:
48.000 inches
-
Tempurature Sensing Element Type:
Capillary tube
-
Mounting Method:
Bracket
-
Contact Action Stimulus:
Increase
-
Nonpile-up Contact Arrangement:
1 pole, single throw, normally open, momentary action
-
Terminal Type:
Quick disconnect, female
-
Contact Load Current Rating:
16.0 amperes resistive load second voltage
-
Contact Load Current Rating:
20.0 amperes resistive load first voltage
-
Contact Adjustability:
Deactuation point not adjustable and actuation point adjustable, preset
-
Contact Adjustment Range:
+58.00/+91.00 actuation point degrees fahrenheit
-
Contact Adjustment Type:
External actuation point knob
-
Contact Stimulus Rating:
63.00 actuation point degrees fahrenheit and 58.00 deactuation point degrees fahrenheit
-
Contact Voltage Rating In Volts:
240.0 ac at sea level second voltage
-
Contact Voltage Rating In Volts:
277.0 ac at sea level first voltage
-
Media For Which Designed:
Gas or liquid
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-00-443-9053