Features
2.125 inches nominal overall length.
Includes quality control certificate of conformance.
Specifications
-
Overall Diameter:
5.750 inches
-
Capillary Tube Length:
72.000 inches
-
Bulb Length:
12.375 inches
-
Bulb Diameter:
0.688 inches
-
Tempurature Sensing Element Type:
Capillary tube-bulb
-
Mounting Facility Circle Radius:
3.250 inches
-
Mounting Method:
Flange
-
Contact Action Stimulus:
Increase
-
Terminal Type:
Tab w/screw
-
Contact Load Current Rating:
5.0 amperes resistive load single voltage
-
Contact Adjustability:
Deactuation point adjustable and actuation point adjustable
-
Contact Adjustment Range:
+50.00/+150.00 actuation point degrees fahrenheit and +50.00/+150.00 deactuation point degrees fahrenheit
-
Contact Stimulus Rating:
6.00 differential point degrees fahrenheit
-
Contact Voltage Rating In Volts:
230.0 ac at sea level single voltage
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-00-247-3057
-
Special Features:
6 feet capillary tube galvanized, hand reset