Features
3.375 inches nominal overall length.
2.000" overall width rectangular.
Includes quality control certificate of conformance.
Specifications
-
Overall Height:
3.531 inches
-
Overall Width:
2.000 inches
-
Body Length:
3.375 inches
-
Capillary Tube Length:
6.000 inches
-
Bulb Length:
8.250 inches
-
Bulb Diameter:
0.375 inches
-
Longest Horizontal Distance Between Mounting Centers:
1.375 inches
-
Tempurature Sensing Element Type:
Capillary tube-bulb
-
Contact Action Stimulus:
Increase
-
Nonpile-up Contact Arrangement:
1 two circuit, one position momentary
-
Terminal Type:
Tab w/screw
-
Contact Load Current Rating:
26.0 amperes resistive load single voltage
-
Contact Adjustability:
Deactuation point adjustable and actuation point adjustable
-
Contact Adjustment Range:
+40.00/+80.00 actuation point degrees fahrenheit and +37.00/+77.00 deactuation point degrees fahrenheit
-
Contact Stimulus Rating:
3.00 differential point degrees fahrenheit
-
Contact Voltage Rating In Volts:
240.0 ac at sea level single voltage
-
Media For Which Designed:
Gas or liquid
-
Style Designator:
Rectangular
-
Federal Supply Class (fsc):
Switches
-
National Stock Number (nsn):
5930-00-511-5535