Circuit Breaker
8150924-2
Multipole-single actuator type body style, 0.380 inches maximum bushing length, 1.500 inches maximum body length, 1.250 inches maximum body width, 0.875 inches nominal center to center distance between terminals parallel to length, 0.625 inches nominal center to center distance between terminals parallel to width
DAC | HCC | DMIL | RNCC |
---|---|---|---|
5 | - | - | 3 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | ZZ |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
INC | FIIG | Concept | Condition |
---|---|---|---|
00136 | A030A0 | - | 1 |
Details
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.Details
A measurement of the longest dimension of a bushing,in distinction from width.Details
A measurement of the longest dimension of the body,in distinction from width.Details
A measurement taken at right angles to the length of the body,in distinction from thickness.Details
The center to center distance between terminals parallel to the length of the item.Details
The center to center distance between terminals parallel to the width of the item.Details
None.Details
The number of poles included in the item.Details
Indicates the type and number of facilities by which the item is mounted.Details
The number of threads on the item per linear inch measured on a line parallel to the thread axis.Details
The maximum current load that each pole is rated to carry continuously.Details
The maximum current load that each pole is rated to carry continuously.Details
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.Details
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.Details
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.Details
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.Details
Indicates the type of electrical condition that will cause the device to trip.Details
The means by which the trip mechanism is released.Details
Denotes the type of trip release action.Details
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.Details
The means provided to reposition the mechanism so that the device is ready to function.Details
Indicates the type of mechanism provided for tripping main contacts.Details
Indicates the type and number of actuators provided for manual control.Details
Denotes the action imparted by actuator operation.Details
An indication of the designated position of the actuator.Details
The basic internal electrical configuration of the trip mechanism.Details
The basic internal electrical configuration of the trip mechanism.Details
A designation that is used for the purpose of general identification of the thread.Details
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.Details
Indicates the type of protection for which the inclosure is designed.Details
The cycles per second /hertz/ of the alternating current.Details
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.Details
Indicates the type and number of terminals for providing electrical connection.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
8150924-2 | 49671 | A | - | 5 | 9 | - | TX |
AP14-1071-2 | 81541 | A | - | 5 | 2 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
P | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
35205 | - | W | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 72D | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5925-00-007-7206?
When the NSN 5925-00-007-7206 was assigned to the Federal Catalog?
Does the NSN 5925-00-007-7206 contain any precious metals?
Does the NSN 5925-00-007-7206 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.