Circuit Breaker
S313C642G30
Multipole-single actuator type body style, 16.000 inches nominal body length, 8.250 inches nominal body width, 4.062 inches nominal body height, 12.000 inches nominal center to center distance between terminals parallel to length, 2.750 inches nominal center to center distance between terminals parallel to width
DAC | HCC | DMIL | RNCC |
---|---|---|---|
A | - | - | 5 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | TX |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
INC | FIIG | Concept | Condition |
---|---|---|---|
00136 | A030A0 | - | 1 |
Details
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.Details
A measurement of the longest dimension of the body,in distinction from width.Details
A measurement taken at right angles to the length of the body,in distinction from thickness.Details
A measurement from the bottom to the top of the body,in distinction from depth.Details
The center to center distance between terminals parallel to the length of the item.Details
The center to center distance between terminals parallel to the width of the item.Details
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.Details
The distance between centerlines of mounting facilities parallel to the length of the item.Details
The distance between centerlines of mounting facilities parallel to the width of the item.Details
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.Details
None.Details
The number of poles included in the item.Details
Indicates the type and number of facilities by which the item is mounted.Details
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.Details
The unusual or unique characteristic/s/ or quality/ies/ of an item which necessitates the establishment of a requirement for special handling.Details
The maximum current load that each pole is rated to carry continuously.Details
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.Details
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.Details
Indicates the type of electrical condition that will cause the device to trip.Details
The means by which the trip mechanism is released.Details
Denotes the type of trip release action.Details
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.Details
The means provided to reposition the mechanism so that the device is ready to function.Details
Indicates the type of mechanism provided for tripping main contacts.Details
Indicates the type and number of actuators provided for manual control.Details
Denotes the action imparted by actuator operation.Details
An indication of the designated position of the actuator.Details
The temperature of the medium surrounding the trip release at which it can be operated continuously.Details
The chemical compound or mechanical mixture properties of which the case is fabricated. please use mrc matt with isac table 0326 in place of this canceled mrc.Details
The cycles per second /hertz/ of the alternating current.Details
Indicates the type and number of terminals for providing electrical connection.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
KL3400PW | 11660 | E | - | 5 | 9 | - | TX |
S313C642G30 | 11660 | A | - | 3 | 9 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
P | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
35205 | - | W | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 72D | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5925-00-022-2641?
When the NSN 5925-00-022-2641 was assigned to the Federal Catalog?
Does the NSN 5925-00-022-2641 contain any precious metals?
Does the NSN 5925-00-022-2641 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.