Circuit Breaker

2991593-5

2991593-5
(NSN) National Stock Number
5925-00-080-5044
Federal Supply Classification
5925 Circuit Breakers
Item Name Code
00136
Schedule B Code
8536200040
Summary

+0.3503 to 0.3537 inches thread pitch diameters, single pole type body style, 0.332 inches minimum and 0.380 inches maximum bushing length, 1.562 inches maximum body length, 0.625 inches maximum body width, 0.906 inches maximum center to center distance between terminals parallel to length

DAC HCC DMIL RNCC
5 - - C
RNVC SADC MSDS RNAAC
1 AF - TX
Identification

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

INC FIIG Concept Condition
00136 A030A0 - 1
Specifications
Thread Pitch Diameters
+0.3503 to 0.3537 inches
Details The minimum and maximum pitch diameter limits of a straight screw thread.
Body Style
single pole type
Details The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Details A measurement of the longest dimension of a bushing,in distinction from width.
Body Length
1.562 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
0.625 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Details The center to center distance between terminals parallel to the length of the item.
Fragility Factor
moderately rugged
Details The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
Mounting Surface To Terminal End Distance
1.700 inches maximum
Details None.
Pole Quantity
1
Details The number of poles included in the item.
Arc Quenching Method
magnetic blowout
Details The means of quenching an arc.
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Details Indicates the type and number of facilities by which the item is mounted.
Storage Type
general purpose warehouse
Details Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
Thread Quantity Per Inch
32
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc single location
Details The maximum current load that each pole is rated to carry continuously.
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Details Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
Details Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.
Circuit Protection Type
overcurrent single location
Details Indicates the type of electrical condition that will cause the device to trip.
Trip Release Method
magnetic single location
Details The means by which the trip mechanism is released.
Trip Release Characteristic
time delay single location
Details Denotes the type of trip release action.
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Details The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.
Ultimate Trip Time Per Pole In Seconds
3.000 minimum and 60.000 maximum single location
Details The ultimate time per pole in which the device must trip,expressed in seconds.
Reset Method
manual
Details The means provided to reposition the mechanism so that the device is ready to function.
Main Contact Tripping Mechanism Type
trip free
Details Indicates the type of mechanism provided for tripping main contacts.
Manual Actuator Type And Quantity
1 toggle
Details Indicates the type and number of actuators provided for manual control.
Actuator Function
trip-reset
Details Denotes the action imparted by actuator operation.
Actuator Position Designation
at pole one
Details An indication of the designated position of the actuator.
Internal Trip Release Configuration
series trip single location
Details The basic internal electrical configuration of the trip mechanism.
Nominal Thread Size
0.375 inches
Details A designation that is used for the purpose of general identification of the thread.
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct and 9.000 maximum at 200 pct and 1.750 maximum at 400 pct single location
Details The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
Details Indicates the type of protection for which the inclosure is designed.
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).
Details The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
Thread Series Designator
unef
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
6 wire hook
Details Indicates the type and number of terminals for providing electrical connection.
Specification/Standard Data
81349-mil-c-39019/1 government specification
Details The document designator of the specification or standard which established the item of supply.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
AP-1-1-5-2-203 C2386 3 - 5 2 - ZG
4885320403 D8385 5 - 5 2 - 9Z
FE540-0010-105N K3902 2 - 5 2 - ZK
2991593-5 10001 5 - C 1 - TX
AP1-1-52-203 81541 E - C 1 - TX
SM3-20-50VDC1 74193 E - C 1 - TX
M39019/01-72 81349 E - 2 2 - TX
MIL-C-39019/1 81349 E - 4 1 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M -
RVC WCC TCC SHC
- 658 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV ROTARY AND MISSION SYSTEMS
CAGE: 25500
AKRON , OH , 44315-0001
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5925-00-080-5044
What is the NIIN of the NSN 5925-00-080-5044?
The National Item Identification Number (NIIN) of the NSN 5925-00-080-5044 is 00-080-5044
When the NSN 5925-00-080-5044 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Wed, Dec 13, 1967
Does the NSN 5925-00-080-5044 contain any precious metals?
Type/content is unknown
Does the NSN 5925-00-080-5044 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA