Circuit Breaker

SCP23

SCP23
(NSN) National Stock Number
5925-00-103-5085
Federal Supply Classification
5925 Circuit Breakers
Item Name Code
00136
Schedule B Code
8536200040
Summary

Single pole type body style, 0.375 inches nominal bushing length, 1.375 inches nominal body length, 0.690 inches nominal body width, 1.020 inches nominal center to center distance between terminals parallel to length, moderately rugged fragility factor

DAC HCC DMIL RNCC
5 - - 5
RNVC SADC MSDS RNAAC
9 - - TX
Identification

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

INC FIIG Concept Condition
00136 A030A0 - 1
Specifications
Body Style
single pole type
Details The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
Bushing Length
0.375 inches nominal
Details A measurement of the longest dimension of a bushing,in distinction from width.
Body Length
1.375 inches nominal
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
0.690 inches nominal
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Center To Center Distance Between Terminals Parallel To Length
1.020 inches nominal
Details The center to center distance between terminals parallel to the length of the item.
Fragility Factor
moderately rugged
Details The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
Mounting Surface To Terminal End Distance
2.035 inches nominal
Details None.
Pole Quantity
1
Details The number of poles included in the item.
Arc Quenching Method
air
Details The means of quenching an arc.
Mounting Facility Type And Quantity
1 threaded bushing
Details Indicates the type and number of facilities by which the item is mounted.
Storage Type
general purpose warehouse
Details Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
Thread Quantity Per Inch
24
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac and 50.0 amperes dc single location
Details The maximum current load that each pole is rated to carry continuously.
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc single location
Details Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc single location
Details Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.
Circuit Protection Type
overcurrent single location
Details Indicates the type of electrical condition that will cause the device to trip.
Trip Release Method
thermal single location
Details The means by which the trip mechanism is released.
Trip Release Characteristic
time delay single location
Details Denotes the type of trip release action.
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
Details The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.
Reset Method
manual
Details The means provided to reposition the mechanism so that the device is ready to function.
Main Contact Tripping Mechanism Type
trip free
Details Indicates the type of mechanism provided for tripping main contacts.
Manual Actuator Type And Quantity
1 push-pull
Details Indicates the type and number of actuators provided for manual control.
Actuator Function
trip-reset
Details Denotes the action imparted by actuator operation.
Actuator Position Designation
at pole one
Details An indication of the designated position of the actuator.
Internal Trip Release Configuration
series trip single location
Details The basic internal electrical configuration of the trip mechanism.
Nominal Thread Size
0.375 inches
Details A designation that is used for the purpose of general identification of the thread.
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Details The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.
Inclosure Protection Type For Which Designed
humidity resistant and salt spray proof and shock resistant and vibration resistant
Details Indicates the type of protection for which the inclosure is designed.
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
Details The temperature of the medium surrounding the trip release at which it can be operated continuously.
Unpackaged Unit Weight
2.000 ounces nominal
Details The measured weight of an item unencumered by packaging or packing material.
Case Material
plastic
Details The chemical compound or mechanical mixture properties of which the case is fabricated. please use mrc matt with isac table 0326 in place of this canceled mrc.
Frequency In Hertz
400.0 single location
Details The cycles per second /hertz/ of the alternating current.
Thread Series Designator
unf
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
2 screw
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
SCP23 37338 5 - 5 9 - TX
109-250-101 79405 E - 5 9 - TX
109-250-101-50A 77342 5 - 5 9 - TX
W23X1A1G-50 77342 E - 3 2 - TX
W23X1A1G-50 2B428 5 - 5 9 - ZZ
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35205 - W -
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
NAUTEL MAINE INC
CAGE: 57655
BANGOR , ME , 04401-5719
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5925-00-103-5085
What is the NIIN of the NSN 5925-00-103-5085?
The National Item Identification Number (NIIN) of the NSN 5925-00-103-5085 is 00-103-5085
When the NSN 5925-00-103-5085 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Mon, Jun 17, 1968
Does the NSN 5925-00-103-5085 contain any precious metals?
Type/content is unknown
Does the NSN 5925-00-103-5085 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA