Power Transformer

41352

41352
(NSN) National Stock Number
5950-00-004-0220
Federal Supply Classification
5950 Coils and Transformers
Item Name Code
32496
Schedule B Code
-
Summary

Not established reliability indicator, 3.750 inches nominal single mounting facility 2nd center group center to center distance between mounting facilities parallel to length, 3.000 inches nominal single mounting facility 2nd center group center to center distance between mounting facilities parallel to width, 400.0 hertz nominal single component frequency rating, three phase to three phase single component input-output phase relationship, delta-delta and delta-wye transformer winding connection type

DAC HCC DMIL RNCC
5 - - 5
RNVC SADC MSDS RNAAC
1 - - TX
Identification

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

INC FIIG Concept Condition
32496 A058B0 1 2
Specifications
Reliability Indicator
not established
Details An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.
Center To Center Distance Between Mounting Facilities Parallel To Length
3.750 inches nominal single mounting facility 2nd center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Width
3.000 inches nominal single mounting facility 2nd center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Frequency Rating
400.0 hertz nominal single component
Details The number of complete cyclic changes,per unit of time,for which an item is rated.
Input-Output Phase Relationship
three phase to three phase single component
Details The relationship of the phase input to the phase output of an alternating current.
Transformer Winding Connection Type
delta-delta and delta-wye
Details Indicates the type of connecting windings in a transformer to be powered by two or three phase currents.
Winding Shielding Method
internal shield grounded to core single component
Details The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.
Body Length
4.600 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
3.880 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Body Height
3.150 inches maximum
Details A measurement from the bottom to the top of the body,in distinction from depth.
Maximum Operating Temp
155.0 deg celsius
Details The maximum temperature at which the item is rated to operate for an extended period of time.
Inclosure Type
fully inclosed
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Facility Quantity
1 1st group
Details The number of mounting facilities provided.
Mounting Facility Quantity
4 2nd group
Details The number of mounting facilities provided.
Mounting Method
threaded hole all groupings
Details The means of attaching the item.
Winding Function And Quantity
1 primary single component and 5 secondary single component
Details The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.
Nominal Thread Size
0.164 inches all groupings
Details A designation that is used for the purpose of general identification of the thread.
Winding Operating Current
200.0 milliamperes ac maximum single component single primary
Details The amount of operating current for which the winding is designed.
Winding Operating Voltage
20.20 ac volts nominal single component 3rd secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
20.20 ac volts nominal single component 4th secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
200.00 ac volts nominal single component single primary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
22.60 ac volts nominal single component 1st secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
22.60 ac volts nominal single component 2nd secondary
Details The value/s/ of the operating voltage applied to the winding.
Special Features
one primary winding; five secondary windings
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Thread Series Designator
unc all groupings
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
18 tab, solder lug
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
860404 82577 5 - 5 2 - TX
984660-1 82577 A - 3 2 - TX
17131 72964 5 - 5 2 - TX
12956 95266 5 - 5 9 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P A - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35355 - W -
RVC WCC TCC SHC
- 595 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
FREED TRANSFORMER CO
CAGE: 73386
PATERSON , NJ , 07522-1513
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5950-00-004-0220
What is the NIIN of the NSN 5950-00-004-0220?
The National Item Identification Number (NIIN) of the NSN 5950-00-004-0220 is 00-004-0220
When the NSN 5950-00-004-0220 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Sat, May 27, 1972
Does the NSN 5950-00-004-0220 contain any precious metals?
Does not contain precious metal
Does the NSN 5950-00-004-0220 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA