Power Transformer

651-1053-000

651-1053-000
(NSN) National Stock Number
5950-00-005-8993
Federal Supply Classification
5950 Coils and Transformers
Item Name Code
32496
Schedule B Code
-
Summary

Not established reliability indicator, 4.800 inches nominal 1st mounting facility 1st center group center to center distance between mounting facilities parallel to length, 7.500 inches nominal 2nd mounting facility 2nd center group center to center distance between mounting facilities parallel to length, 4.200 inches nominal 1st mounting facility 1st center group center to center distance between mounting facilities parallel to width, 1.500 inches nominal 2nd mounting facility 2nd center group center to center distance between mounting facilities parallel to width, 400.0 hertz nominal single component frequency rating

DAC HCC DMIL RNCC
5 - - 5
RNVC SADC MSDS RNAAC
9 - - TX
Identification

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

INC FIIG Concept Condition
32496 A058B0 1 2
Specifications
Reliability Indicator
not established
Details An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.
Center To Center Distance Between Mounting Facilities Parallel To Length
4.800 inches nominal 1st mounting facility 1st center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Length
7.500 inches nominal 2nd mounting facility 2nd center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Width
4.200 inches nominal 1st mounting facility 1st center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Center To Center Distance Between Mounting Facilities Parallel To Width
1.500 inches nominal 2nd mounting facility 2nd center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Frequency Rating
400.0 hertz nominal single component
Details The number of complete cyclic changes,per unit of time,for which an item is rated.
Input-Output Phase Relationship
three phase to three phase single component and single phase to six phase single component
Details The relationship of the phase input to the phase output of an alternating current.
Transformer Winding Connection Type
wye-delta and wye-wye
Details Indicates the type of connecting windings in a transformer to be powered by two or three phase currents.
Body Length
8.125 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
4.625 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Body Height
5.750 inches maximum
Details A measurement from the bottom to the top of the body,in distinction from depth.
Inclosure Type
fully inclosed
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Facility Quantity
4 2nd group
Details The number of mounting facilities provided.
Mounting Facility Quantity
6 1st group
Details The number of mounting facilities provided.
Mounting Method
threaded hole all groupings
Details The means of attaching the item.
Winding Function And Quantity
1 primary single component and 7 secondary single component
Details The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.
Nominal Thread Size
0.190 inches all groupings
Details A designation that is used for the purpose of general identification of the thread.
Winding Operating Voltage
17.40 ac volts nominal single component 1st secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
17.40 ac volts nominal single component 2nd secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
17.60 ac volts nominal single component 3rd secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
30.00 ac volts nominal single component 4th secondary
Details The value/s/ of the operating voltage applied to the winding.
Special Features
1primary winding; 7 secondary windings
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Thread Series Designator
unc all groupings
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
30 threaded stud
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
5950PL0803544 9009H 9 - 6 9 - WP
5043-418 05869 5 - 5 2 - TX
651-1053-000N 97953 A - 3 2 - TX
PEI 9461 13483 5 - 5 2 - ZZ
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P A - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35355 - W -
RVC WCC TCC SHC
- 595 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
NCR CORP POWER SYSTEMS DIV
CAGE: 21908
LAKE MARY , FL , 32746
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5950-00-005-8993
What is the NIIN of the NSN 5950-00-005-8993?
The National Item Identification Number (NIIN) of the NSN 5950-00-005-8993 is 00-005-8993
When the NSN 5950-00-005-8993 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Sun, Jun 11, 1972
Does the NSN 5950-00-005-8993 contain any precious metals?
Does not contain precious metal
Does the NSN 5950-00-005-8993 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products