Power Transformer

865073-0010 13973

865073-0010 13973
(NSN) National Stock Number
5950-00-007-6007
Federal Supply Classification
5950 Coils and Transformers
Item Name Code
32496
Schedule B Code
-
Summary

Not established reliability indicator, 1.300 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 1.300 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 1.100 inches maximum overall height, 20.0 kilohertz nominal single component frequency rating, single phase to single phase single component input-output phase relationship

DAC HCC DMIL RNCC
A - - 1
RNVC SADC MSDS RNAAC
2 - - ZZ
Identification

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

INC FIIG Concept Condition
32496 A058B0 1 2
Specifications
Reliability Indicator
not established
Details An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.
Center To Center Distance Between Mounting Facilities Parallel To Length
1.300 inches nominal single mounting facility single center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Width
1.300 inches nominal single mounting facility single center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Overall Height
1.100 inches maximum
Details The distance measured in a straight line from the bottom to the top of an item.
Frequency Rating
20.0 kilohertz nominal single component
Details The number of complete cyclic changes,per unit of time,for which an item is rated.
Input-Output Phase Relationship
single phase to single phase single component
Details The relationship of the phase input to the phase output of an alternating current.
Body Length
1.600 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
1.600 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Maximum Operating Temp
110.0 deg celsius
Details The maximum temperature at which the item is rated to operate for an extended period of time.
Inclosure Type
fully inclosed
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Facility Quantity
4 single group
Details The number of mounting facilities provided.
Mounting Method
threaded hole single group
Details The means of attaching the item.
Winding Function And Quantity
2 primary single component and 6 secondary single component
Details The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.
Thread Quantity Per Inch
40 single group
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Nominal Thread Size
0.112 inches single group
Details A designation that is used for the purpose of general identification of the thread.
Winding Operating Current
0.3 amperes dc maximum single component 3rd secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Current
0.3 amperes dc maximum single component 4th secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Current
3.9 amperes dc maximum single component 1st secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Current
3.9 amperes dc maximum single component 2nd secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Voltage
12.02 ac volts nominal single component 1st secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
12.02 ac volts nominal single component 2nd secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
9.47 ac volts nominal single component 3rd secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
9.47 ac volts nominal single component 4th secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
98.98 ac volts nominal single component 2nd primary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
98.98 ac volts nominal single component 1st primary
Details The value/s/ of the operating voltage applied to the winding.
Special Features
2 primary windings; 6secondary windings
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Thread Series Designator
unc single group
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
16 turret
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
WE1862 26543 5 - 3 2 - ZZ
16725 72964 5 - 3 2 - ZZ
865073-0010 06481 5 - 5 9 - ZZ
865073-0010 13973 A - 5 9 - TX
14236 95266 5 - 5 2 - ZZ
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35355 - W -
RVC WCC TCC SHC
- 595 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
NORTHROP GRUMMAN SYSTEMS CORPORATION DIV THE NAVIGATION, TARGETING AND SURVIVABILITY DIVISION
CAGE: 06481
WOODLAND HILLS , CA , 91367-6675
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5950-00-007-6007
What is the NIIN of the NSN 5950-00-007-6007?
The National Item Identification Number (NIIN) of the NSN 5950-00-007-6007 is 00-007-6007
When the NSN 5950-00-007-6007 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Wed, Jul 12, 1972
Does the NSN 5950-00-007-6007 contain any precious metals?
Type/content is unknown
Does the NSN 5950-00-007-6007 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA