Power Transformer

5600-0010-000

5600-0010-000
(NSN) National Stock Number
5950-01-028-0299
Federal Supply Classification
5950 Coils and Transformers
Item Name Code
32496
Schedule B Code
-
Summary

Not established reliability indicator, 3.250 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 1.750 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 0.164 inches nominal single group mounting hole diameter, 50.0 hertz minimum single component and 400.0 hertz maximum single component frequency rating, single phase to single phase single component input-output phase relationship

DAC HCC DMIL RNCC
5 - - 3
RNVC SADC MSDS RNAAC
2 - - TX
Identification

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

INC FIIG Concept Condition
32496 A058B0 1 2
Specifications
Reliability Indicator
not established
Details An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal single mounting facility single center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal single mounting facility single center group
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Mounting Hole Diameter
0.164 inches nominal single group
Details The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.
Frequency Rating
50.0 hertz minimum single component and 400.0 hertz maximum single component
Details The number of complete cyclic changes,per unit of time,for which an item is rated.
Input-Output Phase Relationship
single phase to single phase single component
Details The relationship of the phase input to the phase output of an alternating current.
Body Length
3.000 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
2.250 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Body Height
1.500 inches maximum
Details A measurement from the bottom to the top of the body,in distinction from depth.
Inclosure Type
open
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Facility Quantity
4 single group
Details The number of mounting facilities provided.
Mounting Method
flange single group and unthreaded hole single group
Details The means of attaching the item.
Winding Function And Quantity
2 primary single component and 3 secondary single component
Details The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.
Winding Operating Current
1.8 amperes ac maximum single component 1st secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Current
1.8 amperes ac maximum single component 2nd secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Current
2.0 amperes ac maximum single component 3rd secondary
Details The amount of operating current for which the winding is designed.
Winding Operating Voltage
10.55 ac volts nominal single component 3rd secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
115.00 ac volts nominal single component all primary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
21.05 ac volts nominal single component 1st secondary
Details The value/s/ of the operating voltage applied to the winding.
Winding Operating Voltage
21.05 ac volts nominal single component 2nd secondary
Details The value/s/ of the operating voltage applied to the winding.
Terminal Type And Quantity
10 wire lead
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
5600-0010-00 42161 1 - 5 9 - TX
5600-0010-00 23880 5 - 5 2 - TX
5600-0010-00 15253 5 - 5 9 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35355 - W -
RVC WCC TCC SHC
- 595 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
CXR LARUS CORPORATION DIV CXR TELCOM
CAGE: 42161
SAN JOSE , CA , 95112-1361
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5950-01-028-0299
What is the NIIN of the NSN 5950-01-028-0299?
The National Item Identification Number (NIIN) of the NSN 5950-01-028-0299 is 01-028-0299
When the NSN 5950-01-028-0299 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Thu, Sep 23, 1976
Does the NSN 5950-01-028-0299 contain any precious metals?
Type/content is unknown
Does the NSN 5950-01-028-0299 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA