Band Pass Filter
2B136
0.843 inches maximum overall height, 2.250 inches maximum body length, 0.750 inches maximum body width, 0.562 inches maximum body height, 2.000 inches maximum distance between centerlines of mounting facilities parallel to body length, +10.0 to 2000.0 vibration resistance range in hertz
DAC | HCC | DMIL | RNCC |
---|---|---|---|
1 | - | - | 5 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | TX |
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes:a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).
INC | FIIG | Concept | Condition |
---|---|---|---|
00209 | A047B0 | 3 | 1 |
Details
The distance measured in a straight line from the bottom to the top of an item.Details
A measurement of the longest dimension of the body,in distinction from width.Details
A measurement taken at right angles to the length of the body,in distinction from thickness.Details
A measurement from the bottom to the top of the body,in distinction from depth.Details
The distance between centerlines of mounting facilities parallel to the length of the item.Details
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.Details
The distance between centerlines of mounting facilities parallel to the width of the item.Details
The minimum and maximum limits of temperature at which the item is rated for operation.Details
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.Details
The total opposition per function,presented by a source of energy to the input terminals of an item.Details
The total opposition per function,presented by a load to the output terminals of an item.Details
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).Details
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).Details
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.Details
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.Details
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.Details
Indicates the type and number of facilities by which the item is mounted.Details
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.Details
Indicates the functional type and number of terminals providing electrical connection to the item.Details
Indicates the functional type and number of terminals providing electrical connection to the item.Details
Indicates the functional type and number of terminals providing electrical connection to the item.Details
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.Details
A designation that is used for the purpose of general identification of the thread.Details
The chemical compound or mechanical mixture properties of which the body is fabricated.Details
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.Details
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.Details
The maximum direct current voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.Details
The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.Details
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.Details
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
293-1206-010 | 13499 | 1 | - | 3 | 2 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
P | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
58500 | - | P | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 593 | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5915-00-115-3635?
When the NSN 5915-00-115-3635 was assigned to the Federal Catalog?
Does the NSN 5915-00-115-3635 contain any precious metals?
Does the NSN 5915-00-115-3635 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.