Band Pass Filter
TBA-1060-100-4EF1
5.594 inches nominal overall length, 0.750 inches nominal body outside diameter, +5.0 to 500.0 vibration resistance range in hertz, -54.0 to 71.0 deg celsius operating temp range, 250.0 average life rating in hours, 1.02 gigahertz 1st band pass 1st function reference frequency per function
DAC | HCC | DMIL | RNCC |
---|---|---|---|
6 | - | - | 5 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | TX |
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes:a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).
INC | FIIG | Concept | Condition |
---|---|---|---|
00209 | A047B0 | 3 | 1 |
Details
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.Details
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.Details
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.Details
The minimum and maximum limits of temperature at which the item is rated for operation.Details
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.Details
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.Details
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.Details
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).Details
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).Details
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).Details
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).Details
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.Details
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.Details
The value of the average amount of electrical energy per function,which the item may pass or dissipate in continuous operation without degradation of physical or electrical characteristics.Details
The value of the average amount of electrical energy per function,which the item may pass or dissipate in continuous operation without degradation of physical or electrical characteristics.Details
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.Details
Indicates the type and number of facilities by which the item is mounted.Details
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.Details
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.Details
Indicates the functional type and number of terminals providing electrical connection to the item.Details
Indicates the functional type and number of terminals providing electrical connection to the item.Details
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.Details
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.Details
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.Details
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.Details
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.Details
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.Details
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.Details
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.Details
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.Details
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
132694 | 06481 | 1 | - | 5 | 2 | - | TX |
F943APX7 | 80058 | 1 | - | 3 | 2 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
P | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
58500 | - | P | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 593 | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5915-00-722-7928?
When the NSN 5915-00-722-7928 was assigned to the Federal Catalog?
Does the NSN 5915-00-722-7928 contain any precious metals?
Does the NSN 5915-00-722-7928 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.