5.950 inches maximum overall height, 6.500 inches maximum body length, 5.750 inches maximum body width, 5.250 inches maximum body height, 5.375 inches nominal distance between centerlines of mounting facilities parallel to body length, 4.625 inches nominal distance between centerlines of mounting facilities parallel to body width

DAC HCC DMIL RNCC
5 - - 5
RNVC SADC MSDS RNAAC
2 - - TX
Identification

An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes:a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).

INC FIIG Concept Condition
00209 A047B0 3 1
Specifications
Overall Height
5.950 inches maximum
Details The distance measured in a straight line from the bottom to the top of an item.
Body Length
6.500 inches maximum
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
5.750 inches maximum
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Body Height
5.250 inches maximum
Details A measurement from the bottom to the top of the body,in distinction from depth.
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.375 inches nominal
Details The distance between centerlines of mounting facilities parallel to the length of the item.
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.625 inches nominal
Details The distance between centerlines of mounting facilities parallel to the width of the item.
Operating Temp Range
+15.0 to 55.0 deg celsius
Details The minimum and maximum limits of temperature at which the item is rated for operation.
Reference Frequency Per Function
260.0 hertz 1st band pass 1st function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
270.0 hertz 2nd band pass 2nd function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
280.0 hertz 3rd band pass 3rd function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
290.0 hertz 4th band pass 4th function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
300.0 hertz 5th band pass 5th function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
310.0 hertz 6th band pass 6th function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Input Impedance Per Function W/Load
600.0 ohms 1st band pass 1st function
Details The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).
Input Impedance Per Function W/Load
600.0 ohms 2nd band pass 2nd function
Details The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).
Input Impedance Per Function W/Load
600.0 ohms 3rd band pass 3rd function
Details The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).
Input Impedance Per Function W/Load
600.0 ohms 4th band pass 4th function
Details The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).
Input Impedance Per Function W/Load
600.0 ohms 5th band pass 5th function
Details The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).
Input Impedance Per Function W/Load
600.0 ohms 6th band pass 6th function
Details The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).
Output Impedance Per Function W/Source Across Input
34.0 kilohms 3rd band pass 3rd function
Details The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).
Output Impedance Per Function W/Source Across Input
34.0 kilohms 4th band pass 4th function
Details The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).
Output Impedance Per Function W/Source Across Input
34.0 kilohms 5th band pass 5th function
Details The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).
Output Impedance Per Function W/Source Across Input
34.0 kilohms 6th band pass 6th function
Details The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).
Output Impedance Per Function W/Source Across Input
34.0 kilohms 1st band pass 1st function
Details The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).
Output Impedance Per Function W/Source Across Input
34.0 kilohms 2nd band pass 2nd function
Details The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).
Mounting Facility Screw Thread Series Designator
unc
Details A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.
Inclosure Type
encased
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Facility Type And Quantity
4 threaded stud
Details Indicates the type and number of facilities by which the item is mounted.
Insertion Loss At Reference Frequency Per Function In Decibels
22.5 2nd band pass 2nd function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
22.5 3rd band pass 3rd function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
22.5 4th band pass 4th function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
22.5 5th band pass 5th function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
22.5 6th band pass 6th function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
22.5 1st band pass 1st function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Functional Terminal Type And Quantity
2 tab, solder lug ground 3rd function
Details Indicates the functional type and number of terminals providing electrical connection to the item.
Functional Terminal Type And Quantity
7 tab, solder lug input 1st function
Details Indicates the functional type and number of terminals providing electrical connection to the item.
Functional Terminal Type And Quantity
8 tab, solder lug output 2nd function
Details Indicates the functional type and number of terminals providing electrical connection to the item.
Specified Frequencies Of Discrimination Per Function
230.00 hertz 1st band pass and 250.00 hertz 1st band pass and 270.00 hertz 1st band pass and 290.00 hertz 1st band pass 1st function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
240.00 hertz 2nd band pass and 260.00 hertz 2nd band pass and 280.00 hertz 2nd band pass and 300.00 hertz 2nd band pass 2nd function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
250.00 hertz 3rd band pass and 270.00 hertz 3rd band pass and 290.00 hertz 3rd band pass and 310.00 hertz 3rd band pass 3rd function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
260.00 hertz 4th band pass and 280.00 hertz 4th band pass and 300.00 hertz 4th band pass and 320.00 hertz 4th band pass 4th function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
270.00 hertz 5th band pass and 290.00 hertz 5th band pass and 310.00 hertz 5th band pass and 330.00 hertz 5th band pass 5th function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
280.00 hertz 6th band pass and 300.00 hertz 6th band pass and 320.00 hertz 6th band pass and 340.00 hertz 6th band pass 6th function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Nominal Thread Size
0.375 inches
Details A designation that is used for the purpose of general identification of the thread.
Body Material
metal
Details The chemical compound or mechanical mixture properties of which the body is fabricated.
Frequency Band Width Per Function
250.00 hertz 1st band pass and 270.00 hertz 1st band pass 1st function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
260.00 hertz 2nd band pass and 280.00 hertz 2nd band pass 2nd function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
270.00 hertz 3rd band pass and 290.00 hertz 3rd band pass 3rd function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
280.00 hertz 4th band pass and 300.00 hertz 4th band pass 4th function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
290.00 hertz 5th band pass and 310.00 hertz 5th band pass 5th function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
300.00 hertz 6th band pass and 320.00 hertz 6th band pass 6th function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Discrimination At Specified Frequencies Per Function In Decibels
20.0 minimum 2nd band pass and 3.0 maximum 2nd band pass 2nd function3.0 maximum 2nd band pass and 20.0 minimum 2nd band pass 2nd function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
20.0 minimum 1st band pass and 3.0 maximum 1st band pass 1st function3.0 maximum 1st band pass and 20.0 minimum 1st band pass 1st function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
20.0 minimum 3rd band pass and 3.0 maximum 3rd band pass 3rd function3.0 maximum 3rd band pass and 20.0 minimum 3rd band pass 3rd function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
20.0 minimum 4th band pass and 3.0 maximum 4th band pass 4th function3.0 maximum 4th band pass and 20.0 minimum 4th band pass 4th function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
20.0 minimum 5th band pass and 3.0 maximum 5th band pass 5th function3.0 maximum 5th band pass and 20.0 minimum 5th band pass 5th function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
20.0 minimum 6th band pass and 3.0 maximum 6th band pass 6th function3.0 maximum 6th band pass and 20.0 minimum 6th band pass 6th function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Special Features
15 functions; unpackaged unit weight: lb20.000
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Style Designator
rectangular terminal/terminals on one surface
Details The style designation indicating the configuration that most nearly corresponds to the appearance of the item.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
77C701590P001 11402 5 - 5 2 - TX
77C701590-1 03538 1 - 3 2 - HH
77C701590P001 03538 1 - 7 2 - HH
77C701590P001REVC 03538 6 - C 1 - ZZ
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
58500 - P -
RVC WCC TCC SHC
- 593 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
HISONIC, LLC
CAGE: 11402
OLATHE , KS , 66061-3107
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5915-00-995-4759
What is the NIIN of the NSN 5915-00-995-4759?
The National Item Identification Number (NIIN) of the NSN 5915-00-995-4759 is 00-995-4759
When the NSN 5915-00-995-4759 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Tue, Apr 4, 1967
Does the NSN 5915-00-995-4759 contain any precious metals?
Type/content is unknown
Does the NSN 5915-00-995-4759 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2025 Aerospace Shop, Inc. All rights reserved.
Made in USA