Electromagnetic Relay

950115-1

950115-1
(NSN) National Stock Number
5945-00-004-0146
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536410020
Summary

2a single mounting facility thread class, 2.990 inches maximum overall length, 1.630 inches maximum overall diameter, hermetic environmental protection, 1 winding quantity, 1 coil quantity

DAC HCC DMIL RNCC
1 - - 3
RNVC SADC MSDS RNAAC
2 - - TX
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Thread Class
2a single mounting facility
Details A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.
Overall Length
2.990 inches maximum
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Overall Diameter
1.630 inches maximum
Details A measurement of the longest straight line across a circular cross-sectional plane.
Environmental Protection
hermetic
Details The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Coil Quantity
1
Details The number of coils included on the item.
Winding Dc Resistance Rating
190.0 ohms minimum single winding
Details The measured opposition to the flow of direct current offered by the item winding.
Duty Type
continuous
Details Indicates the type of duty provided.
Mounting Facility Type And Quantity
1 threaded bushing single mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Thread Quantity Per Inch
16 single mounting facility
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Nominal Thread Size
0.812 inches single mounting facility
Details A designation that is used for the purpose of general identification of the thread.
Time Delay
0.02 seconds maximum fixed operate and release time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Operating Voltage Rating And Type At Specified Temp
26.5 volts dc 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes dc resistive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
20000.0 ac
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Special Features
high voltage relay
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Thread Series Designator
un single mounting facility
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
5 pin all functions
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
H8S58 18741 1 - 5 2 - TX
T8TH 21621 1 - 5 9 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M P
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
RAYTHEON COMPANY DBA RAYTHEON DIV RAYTHEON AIRBORNE RADARS
CAGE: 82577
EL SEGUNDO , CA , 90245-4501
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5945-00-004-0146
What is the NIIN of the NSN 5945-00-004-0146?
The National Item Identification Number (NIIN) of the NSN 5945-00-004-0146 is 00-004-0146
When the NSN 5945-00-004-0146 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Sat, May 27, 1972
Does the NSN 5945-00-004-0146 contain any precious metals?
Type/content is unknown
Does the NSN 5945-00-004-0146 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA