Electromagnetic Relay
974-0469-290
1.340 inches maximum overall length, 1.078 inches nominal single mounting facility center to center distance between mounting facilities parallel to length, 0.460 inches maximum overall height, 0.900 inches maximum overall width, 0.120 inches nominal single mounting facility mounting slot width, metal case material
DAC | HCC | DMIL | RNCC |
---|---|---|---|
2 | - | - | C |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
1 | - | - | ZF |
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.
INC | FIIG | Concept | Condition |
---|---|---|---|
32512 | A03300 | 1 | 1 |
Details
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.Details
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.Details
The distance measured in a straight line from the bottom to the top of an item.Details
An overall measurement taken at right angles to the length of an item,in distinction from thickness.Details
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.Details
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment. please use mrc matt with isac coding in place of this discontinued mrc.Details
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.Details
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.Details
The number of individual /not electrically connected/ windings.Details
The number of coils included on the item.Details
The measured opposition to the flow of direct current offered by the item winding.Details
Indicates the type of duty provided.Details
The means of quenching an arc.Details
Indicates the type and number of facilities by which the item is mounted.Details
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.Details
Those features,not otherwise specified,which may be required for proper functioning of the item.Details
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.Details
The general configuration and relative position of the facilities provided for mounting the item.Details
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.Details
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.Details
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.Details
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.Details
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.Details
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.Details
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.Details
Indicates the type and number of terminals for providing electrical connection.Details
The document designator of the specification or standard which established the item of supply.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
6711368 | 001JK | 6 | - | 5 | 2 | - | 9Z |
6711368 | S4956 | 4 | - | 5 | 9 | - | ZF |
352250017381 | H0203 | 3 | - | 5 | 2 | - | ZG |
VBE405-75 | H0203 | 1 | - | 5 | 2 | - | ZG |
2B1506-29 | 02289 | 5 | - | C | 1 | - | TX |
EKR307 | 99251 | 5 | - | C | 1 | - | TX |
M5757/10-029 | 81349 | E | - | 2 | 2 | - | TX |
MIL-R-5757/10 | 81349 | E | - | 4 | 1 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
N | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
34430 | - | M | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 658 | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5945-00-102-9371?
When the NSN 5945-00-102-9371 was assigned to the Federal Catalog?
Does the NSN 5945-00-102-9371 contain any precious metals?
Does the NSN 5945-00-102-9371 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.