Electromagnetic Relay

4A-X91

4A-X91
(NSN) National Stock Number
5945-00-115-8144
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536490050
Summary

2a single mounting facility thread class, 1.719 inches nominal overall length, 1.437 inches nominal single mounting facility center to center distance between mounting facilities parallel to length, 1.188 inches nominal overall height, 1.203 inches nominal overall width, 60.0 minimum and 400.0 maximum frequency in hertz

DAC HCC DMIL RNCC
6 - - C
RNVC SADC MSDS RNAAC
1 AC - ZZ
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Thread Class
2a single mounting facility
Details A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.
Overall Length
1.719 inches nominal
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Center To Center Distance Between Mounting Facilities Parallel To Length
1.437 inches nominal single mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Overall Height
1.188 inches nominal
Details The distance measured in a straight line from the bottom to the top of an item.
Overall Width
1.203 inches nominal
Details An overall measurement taken at right angles to the length of an item,in distinction from thickness.
Frequency In Hertz
60.0 minimum and 400.0 maximum
Details The cycles per second /hertz/ of the alternating current.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Coil Quantity
1
Details The number of coils included on the item.
Winding Dc Resistance Rating
4.2 kilohms nominal single winding
Details The measured opposition to the flow of direct current offered by the item winding.
Duty Type
continuous
Details Indicates the type of duty provided.
Mounting Facility Type And Quantity
2 threaded stud single mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Thread Quantity Per Inch
40 single mounting facility
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Nominal Thread Size
0.112 inches single mounting facility
Details A designation that is used for the purpose of general identification of the thread.
Mounting Facility Pattern
in-line single mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
120.0 ac and 30.0 dc
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Thread Series Designator
unc single mounting facility
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
14 pin all functions
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
X941 01556 6 - C 1 - ZZ
B5432-4 05587 1 - 5 9 - TX
X941 05587 6 - 5 9 - TX
4A-X941 99699 6 - 5 2 - TX
B5432-4 99699 1 - 5 2 - TX
X941 99699 6 - 5 1 - TX
404-150PC40 43689 5 - 3 2 - HD
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M P
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
DRI RELAYS INC. DBA DRI RELAYS INC
CAGE: 99699
HAUPPAUGE , NY , 11788-3929
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5945-00-115-8144
What is the NIIN of the NSN 5945-00-115-8144?
The National Item Identification Number (NIIN) of the NSN 5945-00-115-8144 is 00-115-8144
When the NSN 5945-00-115-8144 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Fri, Sep 20, 1968
Does the NSN 5945-00-115-8144 contain any precious metals?
Type/content is unknown
Does the NSN 5945-00-115-8144 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA