Electromagnetic Relay

405-7652PC77

405-7652PC77
(NSN) National Stock Number
5945-00-121-5329
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536490075
Summary

2b second mounting facility thread class, right-hand second mounting facility thread direction, 3.250 inches maximum overall length, 1.750 inches nominal second mounting facility center to center distance between mounting facilities parallel to length, 2.880 inches nominal first mounting facility center to center distance between mounting facilities parallel to length, 4.520 inches maximum overall height

DAC HCC DMIL RNCC
5 - - 5
RNVC SADC MSDS RNAAC
2 - - TX
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Thread Class
2b second mounting facility
Details A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.
Thread Direction
right-hand second mounting facility
Details The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.
Overall Length
3.250 inches maximum
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Center To Center Distance Between Mounting Facilities Parallel To Length
1.750 inches nominal second mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Center To Center Distance Between Mounting Facilities Parallel To Length
2.880 inches nominal first mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Overall Height
4.520 inches maximum
Details The distance measured in a straight line from the bottom to the top of an item.
Overall Width
3.090 inches maximum
Details An overall measurement taken at right angles to the length of an item,in distinction from thickness.
Case Material
plastic
Details The element,compound,or mixture of which the case is fabricated,excluding any surface treatment. please use mrc matt with isac coding in place of this discontinued mrc.
Environmental Protection
watertight
Details The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.
Unthreaded Mounting Hole Diameter
0.199 inches nominal first mounting facility
Details The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.
Center To Center Distance Between Mounting Facilities Parallel To Height
0.500 inches nominal second mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.
Center To Center Distance Between Mounting Facilities Parallel To Height
0.750 inches minimum first mounting facility and 1.500 inches maximum first mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.
Fragility Factor
moderately rugged
Details The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
Frequency In Hertz
60.0 nominal
Details The cycles per second /hertz/ of the alternating current.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Purpose For Which Designed
general
Details The purpose for which the item is designed.
Coil Quantity
1
Details The number of coils included on the item.
Duty Type
continuous
Details Indicates the type of duty provided.
Arc Quenching Method
air
Details The means of quenching an arc.
Mounting Facility Type And Quantity
4 threaded hole second mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Mounting Facility Type And Quantity
6 unthreaded hole first mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Storage Type
general purpose warehouse
Details Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
Cubic Measure
45.392 cubic inches
Details A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.
Thread Quantity Per Inch
32 second mounting facility
Details The number of threads on the item per linear inch measured on a line parallel to the thread axis.
Nominal Thread Size
0.164 inches second mounting facility
Details A designation that is used for the purpose of general identification of the thread.
Mounting Facility Pattern
rectangular second mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Mounting Facility Pattern
rectangular first mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.
Time Delay
5.00 seconds minimum adjustable operate time and 50.00 seconds maximum adjustable operate time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Nonpile-Up Auxiliary Contact Arrangement
1 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the auxiliary nonpile-up contacts including the number of poles or forms.
Auxiliary Contact Maximum Voltage Rating In Volts
480.0 ac
Details The highest voltage at which the auxiliary contacts are rated for normal operation,expressed in volts.
Operating Voltage Rating And Type At Specified Temp
120.0 volts ac 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 15.0 amperes dc resistive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
240.0 ac and 30.0 dc
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load
Details The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.
Energizing Element Power Rating
8.0 watts
Details The amount of electrical energy which the energizing element is capable of dissipating at its rated voltage and/or current during normal operation.
Thread Series Designator
unc second mounting facility
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
11 screw all functions
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
7012ADTW 89020 E - 3 2 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M P
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
HUNTINGTON INGALLS INC DIV NEWPORT NEWS SHIPBUILDING
CAGE: 43689
NEWPORT NEWS , VA , 23607-2700
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5945-00-121-5329
What is the NIIN of the NSN 5945-00-121-5329?
The National Item Identification Number (NIIN) of the NSN 5945-00-121-5329 is 00-121-5329
When the NSN 5945-00-121-5329 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Wed, Oct 23, 1968
Does the NSN 5945-00-121-5329 contain any precious metals?
Type/content is unknown
Does the NSN 5945-00-121-5329 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA