Electromagnetic Relay
RD2 50-VDC
3.180 inches nominal overall length, 2.120 inches nominal overall width, 0.125 inches nominal single mounting facility mounting slot width, hermetic environmental protection, 1 winding quantity, 1 coil quantity
DAC | HCC | DMIL | RNCC |
---|---|---|---|
3 | - | - | 5 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | ZG |
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.
INC | FIIG | Concept | Condition |
---|---|---|---|
32512 | A03300 | 1 | 1 |
Details
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.Details
An overall measurement taken at right angles to the length of an item,in distinction from thickness.Details
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.Details
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.Details
The number of individual /not electrically connected/ windings.Details
The number of coils included on the item.Details
The measured opposition to the flow of direct current offered by the item winding.Details
Indicates the type of duty provided.Details
Indicates the type and number of facilities by which the item is mounted.Details
The general configuration and relative position of the facilities provided for mounting the item.Details
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.Details
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.Details
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.Details
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.Details
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.Details
Indicates the type and number of terminals for providing electrical connection.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
RD2-50D761 | C4751 | 3 | - | 5 | 2 | - | ZG |
RD2-50VC0IL | C4751 | 3 | - | 5 | 2 | - | ZG |
RD2 50-VDC | D1180 | 3 | - | 5 | 9 | - | ZG |
RD2-50D761 | D1180 | 3 | - | 5 | 9 | - | ZG |
RD2-50VC0IL | D1180 | 3 | - | 5 | 9 | - | ZG |
10044179 | 18876 | 1 | - | 3 | 2 | - | TX |
RD2 50-VDC | 73905 | 6 | - | 5 | 9 | - | TX |
RD2-50D761 | 73905 | 6 | - | 5 | 9 | - | TX |
RD2-50VC0IL | 73905 | 6 | - | 5 | 9 | - | TX |
3270854-1 | 53711 | 6 | - | C | 1 | - | ZZ |
3215-1005PC1 | 54X10 | 5 | - | 5 | 2 | - | ZZ |
3215-1005PC1 | 3B150 | 5 | - | 5 | 2 | - | TX |
3215-1005PC1 | 49956 | 5 | - | 5 | 9 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
N | U | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
34430 | - | M | P |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 72D | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5945-00-655-1404?
When the NSN 5945-00-655-1404 was assigned to the Federal Catalog?
Does the NSN 5945-00-655-1404 contain any precious metals?
Does the NSN 5945-00-655-1404 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.