Electromagnetic Relay

MIL-PRF-6106

MIL-PRF-6106
(NSN) National Stock Number
5945-01-020-5009
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536490075
Summary

1.718 inches maximum overall length, 0.625 inches nominal single mounting facility center to center distance between mounting facilities parallel to width, 1.320 inches maximum overall height, 1.025 inches maximum overall width, 0.150 inches nominal single mounting facility mounting slot width, metal case material

DAC HCC DMIL RNCC
4 - - 4
RNVC SADC MSDS RNAAC
1 - - ZZ
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Overall Length
1.718 inches maximum
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.
Overall Height
1.320 inches maximum
Details The distance measured in a straight line from the bottom to the top of an item.
Overall Width
1.025 inches maximum
Details An overall measurement taken at right angles to the length of an item,in distinction from thickness.
Mounting Slot Width
0.150 inches nominal single mounting facility
Details A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.
Case Material
metal
Details The element,compound,or mixture of which the case is fabricated,excluding any surface treatment. please use mrc matt with isac coding in place of this discontinued mrc.
Environmental Protection
hermetic
Details The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.
Fragility Factor
moderately rugged
Details The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Purpose For Which Designed
general
Details The purpose for which the item is designed.
Coil Quantity
1
Details The number of coils included on the item.
Winding Dc Resistance Rating
290.0 ohms nominal single winding
Details The measured opposition to the flow of direct current offered by the item winding.
Duty Type
continuous
Details Indicates the type of duty provided.
Arc Quenching Method
air
Details The means of quenching an arc.
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Storage Type
general purpose warehouse
Details Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
Cubic Measure
2.324 cubic inches
Details A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.
Mounting Facility Pattern
triangle single mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.
Time Delay
0.015 seconds maximum fixed operate and release time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.446 inches nominal single mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).
Details The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
Terminal Type And Quantity
14 wire hook all functions
Details Indicates the type and number of terminals for providing electrical connection.
Specification/Standard Data
96906-ms27400 government standard
Details The document designator of the specification or standard which established the item of supply.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
10126767 A486G 9 - 6 9 - WF
825RL0106 A0199 5 - 5 2 - ZR
X22-306-64 A181N 1 - 5 2 - 9Z
X22-306-64 S3715 1 - 5 9 - ZG
946958-9 06481 5 - C 1 - TU
K-D2A-003 35344 E - C 1 - TX
E410-1219 99699 E - C 1 - TX
359334 25778 5 - C 1 - TX
538115-9 96214 5 - C 1 - TX
974-0574-010 95105 5 - C 1 - TX
MIL-R-6106 81349 E - 5 9 - TX
MS27400-1 96906 E - 5 9 - TX
MS27400-9 96906 E - 2 2 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N U - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M -
RVC WCC TCC SHC
- 658 Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CAGE: 81349
View Products
FAQs
Frequently asked questions for NSN 5945-01-020-5009
What is the NIIN of the NSN 5945-01-020-5009?
The National Item Identification Number (NIIN) of the NSN 5945-01-020-5009 is 01-020-5009
When the NSN 5945-01-020-5009 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Fri, Apr 30, 1976
Does the NSN 5945-01-020-5009 contain any precious metals?
Type/content is unknown
Does the NSN 5945-01-020-5009 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA