Electromagnetic Relay

X22-301-2-26,5

X22-301-2-26,5
(NSN) National Stock Number
5945-01-208-4943
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536490050
Summary

1.320 inches maximum overall length, 1.062 inches minimum single mounting facility and 1.078 inches maximum single mounting facility center to center distance between mounting facilities parallel to length, 0.617 inches maximum overall height, 0.410 inches maximum overall width, 0.120 inches nominal single mounting facility mounting slot width, metal case material

DAC HCC DMIL RNCC
1 - - 5
RNVC SADC MSDS RNAAC
9 - - ZG
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Overall Length
1.320 inches maximum
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Center To Center Distance Between Mounting Facilities Parallel To Length
1.062 inches minimum single mounting facility and 1.078 inches maximum single mounting facility
Details The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.
Overall Height
0.617 inches maximum
Details The distance measured in a straight line from the bottom to the top of an item.
Overall Width
0.410 inches maximum
Details An overall measurement taken at right angles to the length of an item,in distinction from thickness.
Mounting Slot Width
0.120 inches nominal single mounting facility
Details A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.
Case Material
metal
Details The element,compound,or mixture of which the case is fabricated,excluding any surface treatment. please use mrc matt with isac coding in place of this discontinued mrc.
Environmental Protection
hermetic
Details The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.
Fragility Factor
moderately rugged
Details The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Purpose For Which Designed
general
Details The purpose for which the item is designed.
Coil Quantity
1
Details The number of coils included on the item.
Winding Dc Resistance Rating
700.0 ohms nominal single winding
Details The measured opposition to the flow of direct current offered by the item winding.
Duty Type
continuous
Details Indicates the type of duty provided.
Arc Quenching Method
air
Details The means of quenching an arc.
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Storage Type
general purpose warehouse
Details Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
Features Provided
polarized
Details Those features,not otherwise specified,which may be required for proper functioning of the item.
Cubic Measure
0.334 cubic inches
Details A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.
Mounting Facility Pattern
in-line single mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.
Criticality Code Justification
feat
Details The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.
Time Delay
0.004 seconds maximum fixed operate and release time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Operating Voltage Rating And Type At Specified Temp
26.5 volts dc 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
160.0 milliamperes dc lamp load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Load Current Rating At Maximum Rated Voltage
300.0 milliamperes ac resistive load and 2.0 amperes dc resistive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Load Current Rating At Maximum Rated Voltage
750.0 milliamperes dc inductive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Special Features
failure rate level 0.1 percent
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).
Details The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
Terminal Type And Quantity
8 pin all functions
Details Indicates the type and number of terminals for providing electrical connection.
Specification/Standard Data
81349-mil-r-39016/6 government specification
Details The document designator of the specification or standard which established the item of supply.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
X22-301-2-26,5 S3712 1 - 5 9 - ZZ
ER1A008 58657 5 - C 1 - TX
455-0630-010 94756 5 - C 1 - TX
2K2299-57 02288 5 - C 1 - TX
WSBIM6-26-5 02288 5 - C 1 - TX
HFW1230K03 71482 5 - C 1 - TX
HFW1230K03 58614 5 - C 1 - TX
93220310-10 99699 5 - C 1 - TX
641670 89536 6 - C 1 - ZZ
M39016/6-105L 81349 E - 5 9 - TX
M39016/6-105M 81349 E - 5 9 - TX
M39016/6-105P 81349 3 - 2 2 - TX
M39016/6-205L 81349 E - E 8 - ZZ
M39016/6-205P 81349 6 - C 1 - ZZ
M39019/6-205P 81349 6 - C 1 - ZZ
M5757-09-007 81349 E - 5 9 - TX
M5757-10-012 81349 6 - C 1 - ZZ
M5757-9-006 81349 E - 5 9 - TX
M5757-9-057 81349 E - 5 9 - TX
M5757/10-018 81349 E - 5 9 - TX
M5757+09+007 81349 E - 5 9 - TX
MIL-PRF-39016 81349 4 - E 8 - ZZ
MIL-PRF-39016/6 81349 E - 4 1 - ZZ
MIL-PRF-39016E 81349 E - 5 9 - ZZ
MIL-R-39016 81349 E - E 8 - ZZ
MIL-R-39016/6 81349 3 - 5 9 - TX
MILR5757-10 81349 E - 5 9 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N A - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M P
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
BOFORS AB
CAGE: S3715
KARLSKOGA
SWEDEN
View Products
FAQs
Frequently asked questions for NSN 5945-01-208-4943
What is the NIIN of the NSN 5945-01-208-4943?
The National Item Identification Number (NIIN) of the NSN 5945-01-208-4943 is 01-208-4943
When the NSN 5945-01-208-4943 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Wed, May 15, 1985
Does the NSN 5945-01-208-4943 contain any precious metals?
Does not contain precious metal
Does the NSN 5945-01-208-4943 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products