Thermal Resistor

8381K11P003

8381K11P003
(NSN) National Stock Number
5905-00-087-2131
Federal Supply Classification
5905 Resistor
Item Name Code
00309
Schedule B Code
8533400080
Summary

Not established reliability indicator, 1.500 inches nominal terminal length, 0.200 inches nominal body outside diameter, 0.114 inches nominal body width, 0.020 inches nominal terminal diameter, 25.0 deg celsius ambient temp at full rated power

DAC HCC DMIL RNCC
1 - - 3
RNVC SADC MSDS RNAAC
2 - - CT
Identification

A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see resistor (1), current regulating. Excludes:transmitter (1), temperature, electrical resistance and temperature element, resistance meteorological.

INC FIIG Concept Condition
00309 A086A0 1 1
Specifications
Reliability Indicator
not established
Details An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.
Terminal Length
1.500 inches nominal
Details A measurement of the longest dimension of a terminal,in distinction from width.
Body Outside Diameter
0.200 inches nominal
Details The length of a straight line which passes through the center of the body,and terminates at the outside circumference.
Body Width
0.114 inches nominal
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Terminal Diameter
0.020 inches nominal
Details The length of a straight line which passes through the center of a terminal,and terminates at the circumference.
Ambient Temp At Full Rated Power
25.0 deg celsius
Details The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.
Maximum Operating Temp
150.0 deg celsius
Details The maximum temperature at which the item is rated to operate for an extended period of time.
Thermal Time Constant In Seconds
34.0
Details The time required for the temperature of an item to change 63.2 percent of the difference between its initial and final body temperature when subjected to a temperature change under zero power conditions,expressed in seconds.
Power Dissipation Constant In Milliwatts Per Deg Celsius
8.0
Details The ratio,at a specified ambient temperature,of a change in power dissipation in an item to the resultant body temperature change,expressed in milliwatts per degree celsius.
Temp Points For Resistance Readings At Zero Power
-21.5 deg celsius 3rd resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
-40.0 deg celsius 2nd resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 4th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
104.4 deg celsius 8th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 9th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
37.8 deg celsius 5th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 6th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 7th resistance-temperature point
Details The temperature levels at which resistance ratings have been established,under zero power condition.
Zero Power Resistance At Specified Temp
151.5 ohms 9th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
162.0 kilohms 1st resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
24.0 kilohms 3rd resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
246.0 ohms 8th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
1.2 kilohms 6th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
1.8 kilohms 5th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
540.0 ohms 7th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
65.1 kilohms 2nd resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
8.5 kilohms 4th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Zero Power Resistance At Specified Temp
90.0 ohms 10th resistance-temperature point
Details The resistance at a selected temperature,under zero power condition.
Resistance Tolerance At A Specified Temp In Percent
-12.6 to 12.6 4th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-13.7 to 13.7 5th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-14.2 to 14.2 3rd resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-15.1 to 15.1 6th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-16.6 to 16.6 2nd resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-16.9 to 16.9 7th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-17.8 to 17.8 8th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-18.9 to 18.9 1st resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-18.9 to 18.9 9th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Resistance Tolerance At A Specified Temp In Percent
-20.1 to 20.1 10th resistance-temperature point
Details The limits of permissible variation in the electrical resistance value of an item at a selected temperature in percent.
Inclosure Type
encapsulated
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Cubic Measure
0.003 cubic inches
Details A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.
Zero Power Resistance
3.000 kilohms
Details The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0 to 10.0
Details The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.
Reference Temp In Deg Celsius
25.0
Details The temperature at which nominal zero power resistance is specified,expressed in degrees celsius.
Surface Treatment
solder terminal
Details The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.
Style Designator
disk
Details The style designation indicating the configuration that most nearly corresponds to the appearance of the item.
Terminal Type And Quantity
2 wire lead
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
8381K11P3 52531 5 - C 1 - ZZ
1D201 03508 5 - C 1 - ZZ
1D201 01526 1 - 5 9 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N U B -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
35140 - P -
RVC WCC TCC SHC
- 72D 3 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
AMETEK INC DIV AEROSPACE AND DEFENSE
CAGE: 97424
WILMINGTON , MA , 01887-2177
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5905-00-087-2131
What is the NIIN of the NSN 5905-00-087-2131?
The National Item Identification Number (NIIN) of the NSN 5905-00-087-2131 is 00-087-2131
When the NSN 5905-00-087-2131 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Sun, Jan 1, 1961
Does the NSN 5905-00-087-2131 contain any precious metals?
Type/content is unknown
Does the NSN 5905-00-087-2131 contain any hazardous material?
No data in HMIRS
What is the ESD classification of NSN 5905-00-087-2131?
ESD sensitivity

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA