Electrical Resolver
CR90948017
Standard round c body style, 0.9995 inches minimum and 1.0000 inches maximum shoulder diameter, 0.6245 inches minimum and 0.6250 inches maximum pilot diameter, 2.3970 inches nominal overall length, 1.0620 inches nominal flange diameter, 0.0930 inches nominal flange thickness
DAC | HCC | DMIL | RNCC |
---|---|---|---|
5 | - | - | 5 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | ZZ |
An item consisting of a rotor and a stator inductively coupled. It usually has two rotor windings displaced from each other by 90 degrees and two stator windings similarly displaced. The output voltage(s) is a trigonometric function of the input voltage(s) and the angular displacement of the rotor with respect to the stator. See also synchro (as modified) and goniometer, electrical. Excludes:transolver, electrical and potentiometer sine/cosine electrical resolvers.
INC | FIIG | Concept | Condition |
---|---|---|---|
22966 | A07800 | - | 1 |
Details
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.Details
The length of a straight line which passes through the center of a shoulder,and terminates at the circumference.Details
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.Details
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.Details
The length of a straight line which passes through the center of a flange,and terminates at the circumference.Details
A measurement of the smallest dimension of a flange,in distinction from length or width.Details
None.Details
None.Details
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.Details
A measurement of the longest dimension of the shaft,in distinction from width.Details
An alpha and/or numeric designation indicating the size by which the body is identified.Details
The value of the primary excitation voltage for which the stator is rated,expressed in volts.Details
The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.Details
The value of the primary /electrical/ excitation power for which the stator is rated.Details
The cycles per second /hertz/ of the alternating current.Details
The resistance /r/ part of the rotor impedance with the stator open /zro/,expressed in ohms.Details
The resistance /r/ part of the stator impedance with the rotor open /zso/,expressed in ohms.Details
The resistance /r/ part of the rotor impedance with the stator shorted /zrs/,expressed in ohms.Details
The resistance /r/ part of the stator impedance with the rotor shorted /zss/,expressed in ohms.Details
The opposition that the rotor offers to the flow of the direct current,expressed in ohms.Details
The opposition that the stator offers to the flow of direct current,expressed in ohms.Details
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.Details
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.Details
The deviation from 90 degrees perpendicularity of the secondary winding,when excitation is applied to one of the primary windings,expressed in minutes.Details
The limits of permissible deviation of the actual output voltage form the theoretical sinusoidal output voltage divided by the maximum output,expressed in percent.Details
The limits of permissible deviation in angular arc error from electrical zero,expressed in minutes.Details
The measurement taken from the bearing face to the point on the shaft where the weight /load/ is applied.Details
The maximum shaft displacement perpendicular to the shaft axis due to reversal of a specified force applied perpendicular to the shaft axis,and measured at a specified distance from the front surface of the unit.Details
A measurement of the longest dimension of a pilot,in distinction from width.Details
None.Details
None.Details
Indicates the location of the terminal/s/ on the item.Details
The reactance (x) part of the rotor impedance with the stator open (zro).Details
None.Details
The reactance (x) part of the stator impedance with the rotor open (zso),expressed in ohms.Details
None.Details
The reactance /x/ part of the rotor impedance with the stator shorted /zrs/,expressed in ohms.Details
Indicates the type of shaft included on the item.Details
The reactance /x/ part of the stator impedance with the rotor shorted /zss/,expressed in ohms.Details
The ratio of the output voltage to the input voltage at maximum coupling.Details
The force (load) applied perpendicular to the shaft axis to determine radial play.Details
The force (load) applied parallel to the shaft axis to determine end play.Details
Indicates the type and number of terminals for providing electrical connection.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
140-016-0001 | 95542 | A | - | 3 | 2 | - | TX |
CM91034004 | 88818 | 5 | - | 5 | 9 | - | KE |
140-016-0001 | 99932 | 5 | - | 5 | 9 | - | KE |
BZC-11-H-13N/F116 | 99932 | 5 | - | 5 | 2 | - | TX |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
N | A | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
34580 | - | W | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 72D | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5990-00-137-2912?
When the NSN 5990-00-137-2912 was assigned to the Federal Catalog?
Does the NSN 5990-00-137-2912 contain any precious metals?
Does the NSN 5990-00-137-2912 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.