Transmitter Synchro
10TX304C1
Moderately rugged fragility factor, 10 body size, 26.0 nominal rotor input voltage rating in volts, 170.0 milliamperes nominal rotor input current rating, 99.0 milliwatts nominal rotor input electrical power rating, 34.00 nominal zro resistance in ohms
DAC | HCC | DMIL | RNCC |
---|---|---|---|
5 | - | - | 3 |
RNVC | SADC | MSDS | RNAAC |
---|---|---|---|
2 | - | - | KE |
A synchro consisting of a stator and rotor inductively coupled. The electrical output of the stator into a receiver synchro, a control transformer or differential synchro is dependent upon the position of its rotor. Does not include variable resistors, goniometers, variable transformers, or items with dials.
INC | FIIG | Concept | Condition |
---|---|---|---|
02073 | A07800 | 1 | 1 |
Details
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.Details
An alpha and/or numeric designation indicating the size by which the body is identified.Details
The value of the primary excitation voltage for which the rotor is rated,expressed in volts.Details
The value of the primary excitation current for which the rotor is rated,with stator /secondary/ circuit open.Details
The value of the primary /electrical/ excitation power for which the rotor is rated.Details
The resistance /r/ part of the rotor impedance with the stator open /zro/,expressed in ohms.Details
The resistance /r/ part of the stator impedance with the rotor open /zso/,expressed in ohms.Details
The resistance /r/ part of the rotor impedance with the stator shorted /zrs/,expressed in ohms.Details
The opposition that the rotor offers to the flow of the direct current,expressed in ohms.Details
The opposition that the stator offers to the flow of direct current,expressed in ohms.Details
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.Details
The amount of rotary force that must be applied to the actuator to cause rotation,at minus 55 degrees celsius.Details
The amount of rotary force that must be applied to the actuator to cause rotation,at plus 25 degrees celsius.Details
The average torque per angular degree developed between two like items,when one rotor is turned /or displaced/ at 2 degree intervals,between a 10 degree counterclockwise position and 10 degree clockwise position.Details
The reactance (x) part of the rotor impedance with the stator open (zro).Details
The reactance (x) part of the stator impedance with the rotor open (zso),expressed in ohms.Details
The reactance /x/ part of the rotor impedance with the stator shorted /zrs/,expressed in ohms.Part | CAGE | DAC | HCC | RNCC | RNVC | MSDS | RNAAC |
---|---|---|---|---|---|---|---|
16803-3 | 89944 | 2 | - | 1 | 2 | - | KE |
CGH10AS3 | 99932 | 3 | - | 3 | 2 | - | KE |
HMIC | PMIC | ESD/EMI | Criticality |
---|---|---|---|
N | A | - | - |
UFC | HMC | LTL | LCL |
---|---|---|---|
35080 | - | W | - |
RVC | WCC | TCC | SHC |
---|---|---|---|
- | 593 | Z | 9 |
What's Included?
- Certificate of Conformity
- QC Inspection prior to shipping
- On time delivery
- Friendly service to back every order
What is the NIIN of the NSN 5990-00-495-0021?
When the NSN 5990-00-495-0021 was assigned to the Federal Catalog?
Does the NSN 5990-00-495-0021 contain any precious metals?
Does the NSN 5990-00-495-0021 contain any hazardous material?
Can't Find It
If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.